Question Pipe Hello, On the outside of my home I have my backflow device. It has 3/4 copper one side and a Purple pipe on the other. My county uses reclaimed water for irrigation. Would you happen to know
QuestionPurple Pipe QUESTION: Hello, On the outside of my home I have my backflow device. It has 3/4 copper one side and a Purple pipe on the other. My county uses reclaimed water for irrigation. Would you
QuestionWe just bought a new home with a sprinkler system...Hunter SRC Plus controller. We have 6 zones and when we had an inspection done prior to purchasing the home, 2 of the zones didnt work. Since m
hunter pro-c all zones opening at once with medium pressure
QuestionQUESTION: I just bought a house last July and has an irrigation system. This is my first experience with an irrigation system. Last summer it ran perfectly. I hired someone to winterize the system. This past
QuestionHey Jim put a new solinoid in reconnected wires now not working at,all have reset control box can u help AnswerHey Ric, turn off the water and remove the solenoid you installed. Now turn the valve on at the
QuestionHello Jim....Maybe an RC 7bi. The unit is only working in one zone.If I do a manual run through the zones the large wheel will turn and complete the turn as expected, but only the zone already watering will
Questionirritrol SR1 pump relay not working. Checked control line voltage at relay its 24v. Yet when I connect control line (24v) to relay, voltage across relay terminals only reads 1.4v or less. L
QuestionHello, I bought a new construction home back in 2009 and it came with my first irrigation system. I have learned a lot about it by trial and error. Now, I am stumped...The control box is a discontinued model
QuestionI have just recently installed my own irrigation system and every time it is on i have noticed that there is lack of hot water in the house. i have checked to see if the supply to the zone valve box is warm
QuestionI just purchased a house with a sprinkler system. Ive never had one before. I went to start it up and it didnt work so I checked everything and after much looking into I am noticing that when I t
QuestionI have a rain Bird system 6 zones with drains to the lowest point on each zone. Last year i notice that the drain on zone is always wet. Same thing this year, So i check the vale (DV100 vale) on zone five an
QuestionQUESTION: Where is the fuse located? My sprinklers will not come on. Where the time displays it flased fuse, but i can not find a fuse ANSWER: Hi Karen, can you please send me the brand and model of your ir
QuestionQUESTION: Some of my irrigation stations are cycling rapidly on and off on occasion for no reason. My Hunter ICC-800 controller (I think it was new in 2004) is showing no error messages, no stations ar
QuestionI have been having problems with my sprinkler actuators turning on over the years. In the last month, I cant get the unit to turn out manually. This unit is probably 20 years old, never had a pro
QuestionWe have a Hardie Irrigation Total Control 15 station controller. The panel is reading Error Code #1. I downloaded the manual but it doesnt tell you what the error codes are. Where can we get the
QuestionI have had a Hydrotek 2120 irrigation system for 16 years now. The timer toggles between 3 irrigation zones in my yard. Recently it has stopped switching from zone to zone and only directs water to one of th
replacement part for rjc44 sprinkler
QuestionI need a solenoid or perhaps a complete valve for an rjc 44 sprinkler system. Can you tell me if rain jet is still in business and where I can find some drawings and parts list for this system? Regards, &n
Questioni have the timer on 120 volts, how can i hook-up a pump witch require 220 volt. AnswerHi Lou, Open the pump motor and set the power to 115V. If your timer is the mechanic type and can handle an 11/2 HP pum
QuestionHi I have a Hunter X-Core 6 Station Outdoor Irrigation Controller and have it set for 1 run time. After 30min or so the run time repeats itself. It is only just over 12 months old. AnswerH
QuestionQUESTION: I have a Hunter Pro C system. I started it up the other day and station one would run continuously, even when the system was turned off. The only was I could stop it is by turning the water off. T